June 28, 2012 Press Release 50 dB Detector Log Video Amplifier for 500 MHz to 18.0 GHz
|
PMI Model PLVA-500M18G-50 is a 50 dB Detector Log Video Amplifier designed to operate over the 500 MHz to 18.0 GHz frequency range. This model employs planar diode detectors and integrated video circuitry for high speed performance and outstanding reliability. It is of superior construction using state-of-the-art MIC/MMIC technology. The log slope of this DLVA is 50 mV/dB and has a log linearity error of less than ±0.5 dB. The logging range is -40 to +5 dBm with a maximum rise time of 20nsec, maximum settling time of 45 nsec and a recovery time of 150 nsec typical. The unit is offered in a small, compact housing that measures only 2.2" x 1.5" x 0.4"

|
Product Selection Guide (Searchable Database of "Catalog" items)
To view and download -----> Click Here
This file contains a complete listing of all PMI standard products including Amplifiers, Filters, Switch Filter Banks, Switch Products, Limiters, Phase Shifters, SDLVA's, Threshold Detectors, Couplers, Power Dividers, and many others. The search by product type & specification feature allows quick location of the device you need. Direct web links are included which allow easy web site viewing which contains specification listings, data, and test reports.

|
|